<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-06 16-49-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 75 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
7 kHz 68 kHz 18931 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,5 dBr 5,86 dBr 7,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Barbra Streisand - Memory "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 68 kHz MIN: 7 kHz % above 76 kHz: 0,0053 Acquired: 2024/12/06 16.48.50 Total samples: 18931 Equivalent time: 0:15:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 7,2 dBr MIN: 4,5 dBr AVE: 5,86 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2024/12/06 16.48.50) 16.36 16.38 16.40 16.42 16.44 16.46 16.48 0 50 100 Dev. MAX [kHz] 0 2 4 6 8 Pm [dBr]